Special gas mixing
————————
MAP-001 Manual binary gas mixer
2020-05-25

1.1. Product introduction

The binary gas mixer can mix the two gases accurately and evenly according to the proportion required by users, and continuously output the mixed gases. The concentration value of the mixture can be displayed in real time by a high-precision gas concentration analyzer.

It can be widely used in food fresh-keeping, disinfection and sterilization mixture, electronic mixture, electric light source mixture, medical and biological research, purification and smelting of precious metals and other occasions.


1.2. Technical Principle of Mixing

Firstly, the equipment will need mixed A and B gases to enter the pressure stabilization control unit for pressure balancing adjustment. Under the condition of equal pressure, the equipment will mix accurately through the mixed proportional control valve. Finally, the ideal mixed gas will be continuously output through the flow and pressure control unit.


1.3. Main Characteristics

L Standard concentration on-line analyzer, users can monitor the quality of mixing on-line

L Suitable for the Application of Various Gas Technologies

L Freely adjust mixing ratio by knob

L Gas Proportional Concentration on-line Real-time Display with 30-minute Real-time Curve

L The output of mixing pressure can be adjusted according to need.

L Touch screen operation, display and parameter setting, good man-machine interface

Optional RJ45 communication network port data expansion to support MODBUS standard communication protocol

Standard design of L 5U chassis and installation of equipment provide standard size


1.4. Technical Parameter

General model

MAP-001

Applicable medium

N2,CO2,O2.(Other non-toxic and corrosive gases)

Concentration regulation range

0-30%、0-50%、0-100%

Mixed Intake Quantity

2

Maximum flow rate

375SL/min

accuracy

Be better than±1.5%

Intake Pressure Requirements

0.45-0.6MPa

Output pressure

0.25-0.35MPa Adjustable

Inlet/Outlet Caliber

NPT1/4"Internal Thread (Extensible Arbitrary Interface)

backplane configurations

Main gas input interface x1, auxiliary gas input interface x1, mixed gas output interface x1

Net shape size

485mm*420mm*210mm(Length * width * height)

Net weight

17.5kg

Packing

Fully enclosed wooden box, pearl cotton shock box, sealed bag

Working environment temperature

(0~50)℃

Power requirements

External AC 220V power supply

Touch screen size

7-inch Multi-color Resistance Touch Screen

On-line Concentration Detection Function

【Standard】

Shell material

304 stainless steel


1.5. Notes

Matters needing attention:

1. Photos are for reference only. The company has the right to improve its appearance without notice.

2. According to the requirements of different user conditions, the actual parameters of the equipment will be slightly adjusted. Consult the authorizer of the company or the matching company specifically.

3. The quality assurance of the equipment shall be carried out in accordance with the warranty rules.

4. Detailed parameters shall be based on the instructions corresponding to a single device.