Product description:
by the control system, the current signal of the flow sensor is transformed into a digital input converter, according to the change of gas flow to automatically control the dosage of Deodorant (or gain agent) . By setting the frequency, the flow of gas can be guaranteed to keep the uniformity and stability of the concentration of the deodorizer in the maximum and minimum range.
Trial occasion:
Natural Gas odorous agent added: Add to natural gas odorous agent, when there is a natural gas leak people can smell the odor.
The addition of natural gas additive: A certain amount of additive is added into natural gas, after the mixture of the two, a physical reaction occurs, and the combustion value of natural gas is increased to achieve the effect of increasing efficiency and saving energy.
Technical parameters:
FEEDING PRINCIPLE  | follow-up type tracking feeding  | 
Suitable for gas flow range  | 0~500000m3/h  | 
Maximum dosing pressure  | 25MPa  | 
Storage Tank Volume  | non-standard  | 
Structural type  | single pump or double pump optional  | 
power supply  | 380VAC50H,2.0KW  | 
Explosion proof grade  | ExdllBT4  | 
Weight of equipment  | 60kg, without reagent weight  | 
Working environment temperature  | -30℃~45℃  | 
Opening pressure of safety relief valve of drug storage tank  | 60KPa  | 
Equipment installation location  | open air or indoor with good ventilation  | 
Equipment foundation  | >1000×600mm  | 
Software interface:

Working principle:

Key parts accessories: 
Human computer interface: MCGS
PLC programmable controller: Siemens
Metering pump: Haoda Seiko
Cable: Shanghai Panda
CONVERTER: Siemens
Indicator light and alarm: Hangzhou Sanli
Cylinder: 304 Stainless Steel
Relay: OMRON
Case shell: carbon steel plastic spraying or stainless steel
Terminal: Phoenix
Switching power supply: Taiwan Mingwei
Surge protector:Delixi
Pipe valve: 304 stainless steel