1.1. Product introduction
The binary gas mixer can mix the two gases accurately and evenly according to the proportion required by users, and continuously output the mixed gases. The concentration value of the mixture can be displayed in real time by a high-precision gas concentration analyzer.
It can be widely used in food fresh-keeping, disinfection and sterilization mixture, electronic mixture, electric light source mixture, medical and biological research, purification and smelting of precious metals and other occasions.
1.2. Technical Principle of Mixing
Using high-pressure proportional principle and digital MFC technology, through accurate measurement of the instantaneous flow rate of main gas and control of the instantaneous flow rate of auxiliary gas, users can always see the mixing ratio, gas flow rate and gas consumption at a glance, which is suitable for the flexible and changeable requirements of food packaging industry.
1.3. Main Characteristics
L Suitable for the Application of Various Gas Technologies
L The required mixing ratio can be obtained by modifying the parameters of the touch screen.
Reaction speed is very fast, and output flow can be adjusted arbitrarily in the range of measurement.
L Gas Proportional Concentration on-line Real-time Display with 30-minute Real-time Curve
L The output of mixing pressure can be adjusted according to need.
L Touch screen operation, display and parameter setting, good man-machine interface
Optional RJ45 communication network port data expansion to support MODBUS standard communication protocol
Standard design of L 5U chassis and installation of equipment provide standard size
1.4. Technical parameter
General model | MAP-002 |
Applicable media | N2,CO2,O2.(or other non-toxic and corrosive gases) |
Concentration regulation range | 0-30%、0-50%、0-100% |
Mixed Intake Quantity | 2 |
Flow range | 50SL/min,100SL/min,200SL/min |
accuracy | It is better than±0.5% |
Intake Pressure Requirements | 0.45-0.6MPa |
Output pressure | 0.25-0.35MPa adjustable |
Inlet/Outlet Caliber | NPT1/4”Internal Thread (Extensible Arbitrary Interface) |
backplane configurations | Main gas input interface x1, auxiliary gas input interface x1, mixed gas output interface x1 |
Net shape size | 485mm*420mm*210mm(length * width * height) |
Net weight | 17.5kg |
Packing | Fully enclosed wooden box, pearl cotton shock box, sealed bag |
Working environment temperature | (0~50)℃ |
Power requirements | External AC 220V power supply |
Touch screen size | 7-inch Multi-color Resistance Touch Screen |
On-line Concentration Detection Function | 【Standardization】 |
Shell Material | 304 stainless steel |
1.5. Notes
Matters needing attention:
1. Photos are for reference only. The company has the right to improve its appearance without notice.
2. According to the requirements of different user conditions, the actual parameters of the equipment will be slightly adjusted. Consult the authorizer of the company or the matching company specifically.
3. The quality assurance of the equipment shall be carried out in accordance with the warranty rules.
4. Detailed parameters shall be based on the instructions corresponding to a single device.