Product description:
by the control system, the current signal of the flow sensor is transformed into a digital input converter, according to the change of gas flow to automatically control the dosage of Deodorant (or gain agent) . By setting the frequency, the flow of gas can be guaranteed to keep the uniformity and stability of the concentration of the deodorizer in the maximum and minimum range.
Trial occasion:
Natural Gas odorous agent added: Add to natural gas odorous agent, when there is a natural gas leak people can smell the odor.
The addition of natural gas additive: A certain amount of additive is added into natural gas, after the mixture of the two, a physical reaction occurs, and the combustion value of natural gas is increased to achieve the effect of increasing efficiency and saving energy.
Technical parameters:
FEEDING PRINCIPLE | follow-up type tracking feeding |
Suitable for gas flow range | 0~500000m3/h |
Maximum dosing pressure | 25MPa |
Storage Tank Volume | non-standard |
Structural type | single pump or double pump optional |
power supply | 380VAC50H,2.0KW |
Explosion proof grade | ExdllBT4 |
Weight of equipment | 60kg, without reagent weight |
Working environment temperature | -30℃~45℃ |
Opening pressure of safety relief valve of drug storage tank | 60KPa |
Equipment installation location | open air or indoor with good ventilation |
Equipment foundation | >1000×600mm |
Software interface:
Working principle:
Key parts accessories:
Human computer interface: MCGS
PLC programmable controller: Siemens
Metering pump: Haoda Seiko
Cable: Shanghai Panda
CONVERTER: Siemens
Indicator light and alarm: Hangzhou Sanli
Cylinder: 304 Stainless Steel
Relay: OMRON
Case shell: carbon steel plastic spraying or stainless steel
Terminal: Phoenix
Switching power supply: Taiwan Mingwei
Surge protector:Delixi
Pipe valve: 304 stainless steel